Source Factory | Professional Custom Air Filters, Air Dampers, Air Diffusers, and Operating Room Accessories
Product features: Use 0.1 micron MPPS testing instrument for performance testing, product quality is guaranteed; produced in a class 10,000 clean factory, no volatile dust; using high-quality HV filter material, stable efficiency, low resistance, long service life; small size, saving installation space; high strength, light weight, easy to install.
Performance parameters: filtration efficiency full efficiency test (0.1-0.2μm): 99.9995%; most penetrating particle size scanning method (MPPS), filtration grade: U15
Filter material: glass fiber filter paper
Frame: frosted aluminum profile
Dividers: hot melt glue
Working temperature: -20~70℃
Working humidity: ≤99%


| Model | Outline dimensions (A*B*C) | D (mm) | Initial resistance | Rated air volume | |
| H13 | H14 | ||||
| BY-YC 320x320×95 | 320x320x95 | 19 | 150 | 160 | 300 |
| BY-YC 484x484×95 | 484×484x95 | 19 | 150 | 160 | 600 |
| BY-YC 630x630×95 | 630x630x95 | 19 | 150 | 160 | 1200 |
| BY-YC 610x610×95 | 610x610x95 | 19 | 150 | 160 | 1000 |
| BY-YC 915x610x95 | 915x610x95 | 19 | 150 | 160 | 2000 |
| BY-YC 400x400×95 | 400x400x95 | 19 | 190 | 220 | 500 |
| BY-YC 550x550x95 | 550x550x95 | 19 | 190 | 220 | 1000 |
| BY-YC 660x660x95 | 660x660x95 | 19 | 190 | 220 | 1500 |
| BY-YC 1220x610×95 | 1220x610x95 | 19 | 150 | 160 | 1500 |
Note: The above sizes are common specifications, other sizes can be customized and processed as required. The resistance value applies to the rated air volume: ±10% range.
The liquid tank sealing structure can achieve a near-zero leakage installation effect and significantly improve the cleanliness level of the system.
Adopting Mini-pleat partition-less structure, it can stably reach H13/H14 level filtration efficiency.
Optimize the filter material arrangement design to reduce system pressure loss and improve energy efficiency.
Especially suitable for critical clean areas with extremely strict particle control requirements.
The knife frame + liquid tank sealing design ensures no leakage or looseness during long-term operation.
Meet pharmaceutical GMP A/B level area and semiconductor high cleanliness standard requirements.
Liquid tank sealing structure (Gel Seal)
Mini Pleat design without partitions
H13 / H14 high-efficiency filtration grade
Ultra-low leakage rate
High air-tight installation method
Low resistance operation
High dust holding capacity
Support Support OEM/ODM customization
Used for A/B grade clean areas, aseptic filling lines and terminal filtration in key production areas.
Suitable for wafer manufacturing, photolithography workshops and ultra-high clean production environments.
Used in operating rooms, transplant wards and clean medical centers.
Suitable for high-level biosafety laboratories and scientific research clean environments.
Used in high-hygienic food and pharmaceutical packaging environments.
Suitable for high-demand HVAC clean air terminal systems.
The liquid tank sealing structure effectively avoids leakage problems that may occur with traditional sealing methods.
Applicable to ISO Class 3–7 and GMP high-level cleanliness standards.
Low-resistance design reduces system energy consumption and improves operating efficiency.
Maintain stable filtration performance and structural strength during long-term use.
Supports size, efficiency level and frame material customization.
H13 high efficiency grade
H14 super high efficiency grade
Aluminum alloy knife frame
Stainless steel knife frame
Galvanized steel frame
Double sealed structure design
High temperature resistant version
Ultra-low leakage upgraded version
OEM brand customization
Focus on high-efficiency and ultra-high-efficiency air filtration solutions.
Each product is tested for efficiency and leakage.
Serving the pharmaceutical, semiconductor, medical and high-end manufacturing industries.
Adequate inventory of standard products supports batch supply of engineering projects.
Support global brands and engineering supporting customization.
Compared with ordinary sealing methods, liquid tank seals have higher air tightness, which can effectively reduce the risk of leakage and are suitable for high-cleanliness environments.
Yes, it is widely used in GMP clean factories and high-level clean areas of hospitals.
Usually H13 or H14 level (99.95%–99.995%).
The liquid tank sealing structure does not require frequent maintenance under normal use conditions, but the status of the sealing fluid needs to be checked regularly.
Supported, the size, frame and performance parameters can be customized according to project requirements.
Looking for a reliable supplier of liquid tank baffleless high-efficiency filters?
Please provide the following information:
Filter size (length × width × depth)
Filter level (H13/H14)
Installation method Type requirements
Application industries
Purchase quantity
Our engineers will provide professional selection suggestions and quotation plans within 12 hours.
Looking for a reliable manufacturer of air filtration, air distribution, and cleanroom equipment? We provide high-quality products, competitive factory pricing, and flexible OEM/ODM customization services for global customers, meeting the diverse needs of industrial, medical, cleanroom, and HVAC projects.
Address: No. 458 Jiangping Road, Jingjiang City, Jiangsu Province, China
Payment Terms: L/C, T/T, D/P
International Trade Terms: FOB, CFR, CIF, DAP, EXW
Average Lead Time: Peak season: one month; off season: within 15 working days
Nearest Port: Shanghai
Looking for a reliable supplier of air filtration, air distribution, or cleanroom system products? We provide factory-direct pricing, customized OEM/ODM services, and complete engineering project solution support.
Submit your requirements, and our engineering team will provide a dedicated solution and quotation within 12 hours, including detailed product specifications and delivery lead time.